1 The rail frame used for the movement of the electric hoist is selected and designed according to standard GB706-88 by users themselves. Adjust the electric and driven bogies with spacers when installing to ensure the space between the wheel edge and rail flange is 3-5mm
2. In accordance with different hoists, please install the electrical equipments referring to relevant circuit.
3. Points for attention to installation
a. Elastic buffer should be set at two ends of the rail in order to make sure that the hoist does not deviate from the rail when it reaches the end or to prevent bumping into the body.
b. The rail or the connected frame should be equipped with earth-connecting wire as which bare copper wire with the diameterΦ4-5mm or metal conducting-wire with the section no less than 25mm2 can serve.
c. All power circuit in the electric equipment, and the resistance to ground of the controlling circuit should be no less than 1.5Ω per working voltage.