truss girder gantry crasne

 

 

1.Check the traveling mechanisms

2.Test the motor

3.Test run without load(movements、function、lubrication)

4.Test run with load(movements、function、lubrication etc.

5.Deal with the questions after test

6.Turn key of gantry crane

 

2  Preparation of test run

Do the test run before formal using in order to make sure the quality of erection and reasonable and safe using.

(1)The requirements of yard:

a :the span of rails is 35m, and each meter can bear 30t/m wheel pressure. The two sides of rails( in 2m) without obstacle, and the length is up to the users.

b :Check the deviation of rails of crane:

when the crane’s span>10m,the allowable deviation of rail centre line+10mm

the basis point of rail top surface,the allowable deviation+10 mm  between actual elevation and design elevation.

The allowable deviation of span on the two rails under the crane traveling mechanism is +2mm,and the relative elevation≤+1mm。